A small analog-output breakout for experiments that monitor a response to hydrogen sulfide (H2S). It connects to a compatible microcontroller ADC and is intended for qualitative gas-response work, not calibrated concentration measurements.
Important: DFRobot says not to use this module in systems involving personal safety. It is not a certified H2S alarm, exposure monitor, confined-space entry instrument or safety interlock. Do not use it to decide whether air is safe to breathe. The maker also lists sensitivity to benzene and other gases, so a response does not uniquely identify H2S.
Features and specifications
| Model | DFRobot Fermion SEN0568 |
|---|---|
| Target gas | Hydrogen sulfide (H2S); cross-sensitive to other gases |
| Output | Qualitative response, analog voltage |
| Maker's detection range | 0.5–50 ppm; not a calibrated concentration reading |
| Supply | 3.3–5 V DC |
| Operating current | Less than 20 mA |
| Sensitivity | R0 in air / Rs in 50 ppm H2S ≥ 3 |
| Load resistance | 4.7 kΩ |
| Connections | A: analog output; VCC: supply; GND: ground |
| Operating conditions | −10 to 50 °C; 15–90% RH, non-condensing |
| Board dimensions | 13 × 13 × 2.5 mm |
Use and handling
Remove the protective film before use. Check the controller ADC voltage limit before connecting the analog output. The official Arduino example reads raw analog values; it does not convert them into calibrated ppm. Allow more than five minutes of warm-up on first power-up, and more than 24 hours after prolonged storage.
Avoid silicone vapours, concentrated corrosive gases, alkalis, halogens, water, condensation, freezing and strong impacts. Do not leave the sensor in prolonged hot, humid or heavily polluted conditions.
Package Includes
- 1 × DFRobot Fermion SEN0568 H2S sensor breakout
- 1 × separate 2.54 mm pitch pin header
The header is supplied separately and needs soldering. Controller, wires and power supply are not included.