DFRobot Gravity SEN0514 ENS160 Air Quality Sensor
A compact I2C module for indoor air-quality projects. The ENS160 metal-oxide multi-gas chip processes its gas response into total volatile organic compounds (TVOC), an equivalent carbon dioxide value (eCO2) and a five-level air quality index (AQI). The Gravity four-pin connector makes it easy to wire to a compatible controller.
Know what the readings mean: eCO2 is an estimate calculated from the response to VOCs and hydrogen. It is not a direct CO2 measurement and this module is not an NDIR CO2 sensor. Use it for air-quality trends and experiments, not as a substitute for a dedicated gas alarm or a safety assessment. Temperature and humidity compensation values must be supplied by your program; the module does not provide temperature or humidity measurements.
Features and specifications
| Model | DFRobot Gravity SEN0514 |
|---|---|
| Sensor chip | ScioSense ENS160, metal-oxide multi-gas sensor |
| Outputs | TVOC, calculated eCO2, AQI and operating status |
| Supply | 3.3–5.5 V DC |
| Working current | 29 mA |
| Interface | I2C |
| I2C address | 0x52 or 0x53, selected on the board |
| TVOC output range | 0–65000 ppb |
| eCO2 output range | 400–65000 ppm, calculated equivalent value |
| AQI output | Five levels, 1 to 5 |
| Operating temperature | −40 to 85 °C, maker specification |
| Operating humidity | 5–95% RH, non-condensing |
| Board size | 30 × 22 mm |
| Mounting holes | 15 mm pitch, 3 mm aperture |
Connection and first use
Connect + to a suitable supply, − to ground, C to I2C SCL and D to I2C SDA. Check your controller's electrical limits and the selected address before powering up. The official Arduino example uses address 0x53 and the DFRobot_ENS160 library. The Gravity SEN0514 board uses I2C; the library's SPI examples for the separate Fermion version do not add an SPI interface to this board.
Read the sensor status before using the outputs. Normal power-on warm-up is about three minutes. Initial start-up lasts the first full hour of operation; the completion state is stored after 24 hours of continuous operation, so an earlier power interruption can cause initial start-up to resume. Supply current ambient temperature and relative humidity to the library's compensation function rather than assuming its example values match your room.
The onboard algorithm includes automatic baseline correction. Common projects include indoor air-quality logging, ventilation experiments and home-automation prototypes. Output ranges are not accuracy guarantees.
Package Includes
- 1 × DFRobot Gravity SEN0514 ENS160 air quality sensor board
- 1 × Gravity four-pin I2C/UART sensor connector cable
Controller, power supply and other accessories are not included. The supplied cable's I2C/UART name does not mean the SEN0514 supports UART.